MAGNETIC RESONANCE IMAGING OF THE KNEE AND DIAGNOSTIC ACCURACY



Abstract

Magnetic Resonance Imaging is increasingly utilised for the assessment of knee pathology. The aim of this study was to review our entire knee MRI scans and to assess the accuracy of diagnosis when compared with operative diagnosis. Using data from the radiology department and medical records (public and private) all patients having knee MRI scans in a 6-year period were identified.

There were 956 scans performed on 930 patients. Scan diagnosis, operative diagnosis and diagnostic accuracy were assessed. Of the scanned patients 181 (19.5%) had normal scans and of these 168 (92.8%) were accurately diagnosed as normal. The remaining 749 (80.5%) had an abnormality noted on scan and of these 298 (39.8%) proceeded on to surgery. Of those patients having surgery, diagnosis at surgery was found to exactly match the results of the scan in 163 (57.0%) patients. Furthermore 51.5% of patients with a diagnosis of meniscal degeneration by scan actually had a meniscal tear at operation. However the sensitivity for diagnosis of ACL tears was 89.0% and that of medial meniscal tears was 90.6%.

MRI diagnosis is far from infallible and clinicians should be conscious of its limitations. However it is particularly reliable in confirming the lack of pathology within a knee with an accuracy of 93%. It also has high sensitivity for diagnosis of ACL and meniscal tears.

Correspondence should be addressed to the editorial secretary: Associate Professor Jean-Claude Theis, Department of Orthopaedic Surgery, Dunedin Hospital, Private Bag 1921, Dunedin, New Zealand.