EARLY RESULTS OF BIRMINGHAM HIP RESURFACING



Abstract

To review the early functional results of Birmingham hip resurfacing. First 116 hips (98 patients), a cohort of consecutive patients prospectively underwent BHR in a single arthroplasty Surgeon’s practice in a University Hospital outside Birmingham. Inclusion criteria fit and active patients. 98 patients mean age 50 years (range 19–67). Pathology OA 85%, Perthes 7%, DDH 4.7% & SUFE 2%. Mean follow-up 30 months (range 12–45). Scoring systems used were Harris hip score (HHS), WOMAC & SF36.

HHS: mean pre-arthroplasty 47 (range 10–73), one year 99 (n=57), at 2 years 97.3 (n=26) and at third year 100 (n=3), statistically significant improvement (P=0.001).

WOMAC: pain: pre-op score 18.8, at 1 year 5.6 and second year 5.7. Stiffness: pre-op 8.5, 1 year 2.7 & 2nd year 2.7. Physical: 49.3, 1 year 23.4 & 2nd year 22.6.

This shows a statistically significant improvement in pain score (p=0.025) and physical function score (p=0.025).

SF-36 one-year post op, when analysed against an age/sex match control group normal values using a 2 tailed ‘t’ Test, seven of the eight domains showed no statistical significance. Only the Social Functioning domain showed a statistically significant result (p=0.011).

One fracture following a fall (patient had deep cysts in proximal head now such patients are not offered BHR), one dislocation following RTA and one AVN in a 50 years old post menopausal lady.

Birmingham hip resurfacing can provide excellent level of activity and patient satisfaction. A long-term study is needed to evaluate the long-term benefit and survivorship.

The abstracts were prepared by Mr Richard Buxton. Correspondence should be addressed to him at Bankton Cottage, 21 Bankton Park, Kingskettle, Cupar, Fife KY15 7PY, United Kingdom