THE MODIFIED LATARJET PROCEDURE FOR INSTABILITY WITH GLENOID BONE LOSS



Abstract

Between 1996 and 2001 we used a modification of the Latarjet procedure to treat 70 patients with bony insufficiency of the glenoid. Our modification involves detaching a long piece of coracoid and rotating it to match its concave inferior surface with the surface of the glenoid. The coracoid graft is placed extra-articularly and the capsule repaired with bone anchors to the edge of the glenoid.

Postoperatively no sling is applied and rehabilitation is started early.

At a mean of 24 months (9 to 72) patients were clinically reviewed and assessed on the Walch-Du Play score. The results were excellent in 68%, moderate in 6% and poor in 1%. There were no redislocations.

The results were most satisfactory in this group of patients, most of whom participated in contact sports, where soft tissue procedures (e.g., open and arthroscopic Bankarts) carry unacceptable failure rates.

The abstracts were edited by Prof. M.B.E. Sweet. Correspondence should be addressed to him at the Department of Orthopaedic Surgery, Medical School, University of the Witwatersrand, 7 York Road, Parktown, 2193 South Africa