THE PASSAGE OF BACTERIA THROUGH SURGICAL DRAPES



Abstract

The passage of bacteria through surgical drapes is a potential cause of wound infection. Previous studies have shown that liquids and human albumin penetrate certain types of drapes12. We studied the passage of bacteria through seven different types of surgical drape and an operating tray. We also studied the effect of different wetting agents on the passage of bacteria through wet reusable woven drapes. Bacteria were grown on an overfilled whole horse blood agar plate. The plate was covered with the drape to be tested and a second agar plate was inverted and placed on the drape. After 30 minutes the second agar plate was removed, incubated and inspected for bacterial growth. The experiment was repeated removing the second plate at 60 minutes and then again at 90 minutes. The entire experiment was repeated for each drape and then for each wetting agent.

Bacteria easily penetrated all the woven reusable fabrics within 30 minutes. The disposable non-woven drapes proved to be impermeable up to 90 minutes, as did the operating tray.

Chlorhexidine and Povidone-Iodine were demonstrated to slow, but not stop the passage of bacteria through reusable woven drapes. Normal saline and human blood accelerated the passage of bacteria through reusable woven drapes. We recommend the use of non-woven disposable drapes or woven drapes with an impermeable operating tray, in all surgical cases.

The abstracts were prepared by Mr Simon Donell. Correspondence should be addressed to him at the Department of Orthopaedics, Norfolk & Norwich Hospital, Level 4, Centre Block, Colney Lane, Norwich NR4 7UY, United Kingdom

Mackintosh CA and Lidwell OM. The evaluation of fabrics in relation to their use as protective garments in nursing and surgery. III. Wet penetration and contact transfer of particles through clothing. J Hygiene1980; 85: 393–403 Google Scholar

Ha’eri GB, Wiley AM. Wound contamination through drapes and gowns. A study using tracer particles. Clin Orthop1981; 154: 181–184 Google Scholar