DAMAGE TO CHONDROCYTES OF OSTEOCHONDRAL PLUGS DURING MOSAICPLASTY



Abstract

Introduction: Osteochondral mosaicplasty is gaining popularity as a treatment for isolated chondral defects in femoral condyles. Most systems use a metal punch to impact the osteochondral grafts in pre-drilled defects. Damage to the chondrocytes during impaction grafting is of concern and new methods are being sort to minimise this deleterious effect. This study was designed to see if using a plastic punch instead of a metal punch reduces the extent of chondrocyte damage in osteochondral mosaic plasty.

Method: Ten fresh sheep knees were used to harvest 30 osteochondral plugs using the COR system. The opposite condyles were then prepared to receive the osteochondral grafts. Ten plugs were impacted using a metal punch and ten using a plastic punch. The ten remaining plugs were used as controls. The plugs were then recovered and incubated for 24 hours before being stained with MTT. The stained cartilage was then photographed using a digital macroscope. The images were interpreted using a graphics analysis programme.

Results: There was no significant difference in the extent of chondrocyte damage between the two groups. However the extent of chondrocyte damage in the impacted groups was significantly greater than the control group.

Conclusions: Impaction grafting clearly damaged the chondrocytes of the osteochondral plug. In our study using a plastic punch did not reduce the extent of chondrocyte damage during mosaicplasty.

The abstracts were prepared by Professor A. J. Thurston. Correspondence should be addressed to him at the Department of Surgery, Wellington School of Medicine, PO Box 7343, Wellington South, New Zealand