NON-CEMENTED THREADED CUP WITHOUT BONE GRAFTING IN DYSPLASTIC HIPS



Abstract

The aim of this study was to analyse the long-term results of a cementless conical threaded cup with elevated inlay-rim, without bone grafting in joint replacement of dysplastic compared to non-dysplastic hips, and concerning the survival rate and the rate of cup migration.

Most techniques of joint replacement of dysplastic hips contain bone grafting with more or less large-scale procedures. Without bone grafting, medialisation of the cup is often necessary. The conical threaded Link-V cup has the opportunity of stabilising the joint by using a polyethylene inlay with an elevated rim so that implantation in high angles of flexion and anteversion is possible. This is a technically easy procedure in dysplastic hips, but higher rates of loosening and cup migration are possible.

A cementless conical threaded cup (Link V) with elevated inlay-rim was followed in 36 dysplastic hips (DH) and 167 non-dysplastic osteoarthritic hips (OA) over a minimum follow-up of five years. Mean follow-up in DH-hips was 8.4 2.3 years and in OA-patients 8.6 3.2 years. Survival analysis was performed and cup migration was radiographically analysed using the method of Nunn et al.

The 10-year survival rate of the cup was 87% in DHhips compared to 92% in OA-hips. Luxation occurred in three OA-joints and none in DH-hips. Radiological cup migration was seen in 75% of DH-hips and in 70% of OA-joints. A change of the angle of flexion (mostly decrease) of more than two degrees was found in 50% of DH-hips and in 72% of OA-joints. There was vertical migration of more than 2 mm in 75% of DH-hips and in 70% of OA-hips, and a horizontal migration of more than 2 mm in 45% of DH-joints and in 40% of OA-hips. A radiolucent line of minimum 2 mm was seen in one case of each group.

Using a cementless threaded cup with elevated inlayrim is a practicable and technically easy procedure for treatment of destroyed dysplastic hips. Although cup migration is frequent in dysplastic and non-dysplastic hips, failure-rate is still acceptable but tends to be higher in dysplastic than in non-dysplastic hips.

The abstracts were prepared by David P. Davlin. Correspondence should be addressed to him at the Orthopedic Clinic Bulovka, Budínova 2, 18081 Prague 8, Czech Republic.