header advert
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Get Access locked padlock

Intra-operative awakening to monitor spinal cord function during scoliosis surgery. Description of the technique and report of four cases



Download PDF

Abstract

We used a modification of the wake-up test to monitor spinal cord function in 102 consecutive scoliotic patients undergoing Harrington instrumentation. Four patients were found to have a neural deficit when they were awakened during the operation. Three recovered immediately after partial release of the distracting force; one required immediate removal of the rod and was left with a slight neural deficit. Using our method, we have encountered no problem in performing the wake-up test, although attention is drawn to the difficulty in repeating the test if the patient is re-anaesthetised with diazepam. There were no false negative results in this series.

For access options please click here