header advert
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Get Access locked padlock

Failure of sliding nail-plate fixation in subcapital fractures of the femoral neck



Download PDF

Abstract

A retrospective study of 200 cases of subcapital fracture of the neck of the femur treated by sliding nail-plate fixation has been carried out. Failure of fixation within three months occurred in forty-two cases (21 per cent). These failures could, in part, be attributed to a combination of the severity of the fracture and various imperfections in technique. The age of the patient and the angle of the nail-plate had no significant effect on the result.

For access options please click here