HARRINGTON'S INSTRUMENTATION AS A SALVAGE PROCEDURE FOR PSEUDARTHROSES IN SPINE FUSIONS FOR SCOLIOSIS



Download PDF

Abstract

1. Twelve patients with suspected pseudarthroses in previous spine grafts were subjected to operation.

2. Correction of the curves was produced by Harrington's instrumentation at the sites of pseudarthroses, osteotomies and fractures.

3. A significant increase in stature was produced in all the patients.

4. Harrington's hooks were safely inserted into cavities cut in intact portions of previous grafts.

5. Most patients were able to leave hospital in less than four weeks.

6. Deliberate bending of the Harrington rods has not led to subsequent fracture of the rod.

7. A sliding scoliosis fusion frame is described. It reduces friction during correction and it reduces haemorrhage during surgery.